EVS Multicam Version 10.04 – Configuration Manual
EVS Broadcast Equipment SA January 2011
Issue 10.4.A
85
3.20.9 IP ADDRESS
Possible value: xxx.xxx.xxx.xxx
When the Epsio connection is enabled via the External Offside parameter, the IP
Address of the Epsio workstation has to be entered in this parameter to allow the
communication between the EVS server and the Epsio workstation to be
established.
3.20.10 DEFAULT TOOL
Possible values: Offside (default), Arrow, Circle, Graphics
When the Epsio connection is enabled via the External Offside parameter, this
parameter specifies the tool to be activated by default in the Epsio menu on the
Remote Panel. It is recommended to keep the default value.
For more information on Epsio, refer to the Epsio user manual.
3.20.11 AUTO MARK
Possible values: Off / On (default)
When the Auto Mark setting is set to ‘On’, a cue point is automatically defined on
the record train every time the Epsio operator enters the Epsio menu on the LSM
Remote panel.
3.21 OVERVIEW
The XNet network is composed by several servers all connected with a
75-Ohm coaxial cable (BNC). The exchange between systems is operated through
the SDTI interface at 540 or 1485 Mbps.
The XNet network requires a network server dedicated to the management of the
database shared among all servers. This doesn’t require an extra server, but it
has to be assigned to 1 server on the network. If this system disconnects, another
server will automatically take over. These settings can be found in the
Configuration option of the EVS Maintenance menu. For details about the setup of
XNet network, please refer to the XT Tech Ref Hardware manual.