Evs MulticamLSM Version 10.04 - January 2011 Configura Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 98
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
EVS Multicam Version 10.04 – Configuration Manual
EVS Broadcast Equipment SA January 2011
Issue 10.4.A
7
AUDIO METERS ON OSD
Possible values: Yes (default) / No
This parameter enables/disables the display of audio meters at the bottom of each
output monitor.
AUDIO METERS ADJ. (DB)
Possible range: -83.2dB to 0dB. Default: 0dB
This parameter allows adjusting the sensitivity of audio meters on the OSD of the
output monitors. A positive value means that the meters will be more sensitive.
2.2.4 NETWORK SETTINGS
You can also define the Clip edit by network setting on page 3.1, F6 of the setup
menu on the Remote Panel. You will find a description of these settings in the
Multicam user manual.
CLIP EDIT BY NETWORK
Possible values: Disable (default) / Enable
If this function is enabled, other users on the network can trim, rename, delete,
etc. your clips, or modify the keywords and ranking assigned to your clips. If
disabled, only the local operators can modify or delete clips on the server and edit
their metadata.
2.2.5 CLIP MANAGEMENT SETTINGS
You can also define most of the Clip management settings on pages 3.1 to 3.3 of
the setup menu on the Remote Panel. You will find a description of these settings
in the Multicam user manual.
DEFAULT COPY/MOVE
The Default Copy/Move parameter allows specifying whether the copy operations
should be executed preferably using the SDTI or the HCTX GigE network.
If the value selected is ‘SDTI’, the copy operations are first executed through the
SDTI network. If the SDTI network is temporarily unavailable, the transfer is then
tried through the HCTX GigE interface. Transfers to GigE targets will always be
performed via the HCTX GigE interface.
If the value selected is ‘GbE’, the copy operations are first executed via the HCTX
GigE interface. If the transfer is not possible (ports not connected, IP address
unknown, no more connection ports are available), the transfer is then tried
through SDTI.
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 97 98

Commentaires sur ces manuels

Pas de commentaire