GPIs IN - Delay
Description Specifies the time (number of seconds and/or frames) that the
server will wait after receiving the input signal before executing
the input-related function.
Values 00s00fr to 02s00fr
Disable
Default value Disable
GPIs OUT - Function
Description Specifies the function that activates the output line.
Values The following functions can be triggered by a GPI OUT:
Replace
GPIs OUT - Type
Description Specifies the type of GPIoutput signal that will trigger the
specified function.
Values The following values are possible:
close
The level changes to high level at
activation.
close
pulse
A rising edge pulse is generated at
activation.
open
The level changes to low level at
activation.
open
pulse
A falling edge pulse is generated at
activation.
GPIs OUT - Advance
Description Defines the time (number of seconds and/or frames), at which
the output will be generated ahead of the timecode linked to the
output line.
Values 00s00fr to 02s00fr
Disable
Default value Disable