6
Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn
GPIS OUT ADVANCE AND DURATION
p.8.GPI OUT Settings
GPI# Advance Duration
1[F1]Disable [F5]01s00fr
[F2]Disable [F6]01s00fr 2
3[F3]Disable [F7]01s00fr
le [F8]01s00fr 4[F4]Disab
[
GPI OUT Settings p.8.7
Duration
[F5]01s00fr
6[F2]Disable [F6]01s00fr
1s00fr
GPI# Advance
5[F1]Disable
7[F3]Disable [F7]01s00fr
8[F4]Disable [F8]0
[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn
GPI OUT ADVANCE
s: Disable (default), or 00s01fr to 02s00fr
Possible values: Disable, or 00s01fr to 02s00fr. Default: 01s00fr.
for pulse GPIs.
Possible value
Possible values: up to 2 seconds, frame by frame (like GPI delay)
When a GPI out advance setting is set (for instance 2 fr.), the GPI OUT is sent 2
frames in advance.
GPI PULSE DURATION